Automated Measurement Of The Density Of Vessels On Whole Slide Images Of Paediatric Brain Tumours
Abstract
Introduction/ Background
Microvasculature is known to have a prognostic significance in many brain tumours. It is important to be able to quantify it in a reproducible way on biopsy samples and, if possible, through noninvasive imaging techniques.
Aims
A quantitative and reproducible way to assess the microvasculature of biopsy samples of human paediatric brain tumours is needed, in order to help diagnosis (possibly give a hint of the grading of the tumours) and to see if a correlation exists with a perfusion MRI (ASL) signal. The method should be applicable to standard whole-slide images of samples immunostained with CD34 marker over haemalum. Such slides are usually very fragmented, which makes the manual measurement of density particularly tedious and error-prone.
Methods
Our method starts with a precise determination of the zones of tissue on the whole-slide image. Then we measure their area and we calibrate automatically the staining optical densities and the background colour. Automated detection, measurement and counting of vessels takes place, based on a colour deconvolution [1] followed by automatic thresholding [4] and finally morphological operations to remove artefacts (e.g., dust). In order to deal with the large size of whole-slide images, many of which exceed the capacity of the computer’s memory, we proceed on rectangular extracts of the whole image. The whole treatment was performed on a standard desktop computer with 16 GiB of RAM [2]. In the end, masks of areas considered as tissue and as vessel walls and lumina are produced and uploaded, along with the virtual slide, to a webserver. This allows the pathologist to check the quality of segmentation from his office using a simple JavaScript-capable web browser. We tried two formats for web serving: DeepZoom (which can be served directly by a webserver) and pyramidal TIFF (which needs to be served by a modified version of IIPImage server [3] because lossless compression of the masks was used to preserve both disk space and image quality).
Results
Only a few parameters have to be chosen, once and for all samples (e.g., the minimal acceptable size of a blood vessel fragment), which makes the method more robust than assessment by a (panel of) human expert(s). The automatic calibration steps enable one to deal with a heterogeneous set of slides (e.g., slight differences in background colour and staining). The method uses only open-source software. It is easy to extend or improve and not tight to a single immunomarker.
We applied the method to 129 paediatric brain tumours of 8 different types and 3 locations (posterior fossa, thalamus, hemispheres) — 185 samples in total. For each patient, the density of microvessels in the sample is compared to the cerebral blood flow as assessed by preoperative perfusion-weighted-imaging using arterial-spin-labeling. We find a good correlation between microvascular density, MRI data and tumour grading. The microvascular density is broadly distributed among the samples.
Visualisation in a web browser is slightly more fluid when images are uploaded in the DeepZoom format rather than as pyramidal TIFF images, but the former consumes roughly 20 times more disk space and needs the transfer of a very large number of files after each modification, which is less tractable.
Downloads
References
299.
[3] Ruven Pillay, IIPImage server[Internet], 2016. [cited 30-01-2016]. Available from: http://iipimage.sourceforge.net/
[2] Deroulers, C., et al., Analyzing huge pathology images with open source software, Diagnostic Pathology 2013, 8:92.
[4] Kapur J.N., Sahoo P.K., Wong A.K.C., A New Method for Gray-Level Picture Thresholding Using the Entropy of the Histogram,
Comput vision graphics image process 1985, 29:273–285
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish with this journal agree to the following terms:
1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).
4. In case of virtual slide publication the authors agree to copy the article in a structural modified version to the journal's VS archive.